E-ISSN 2414-6013 | ISSN 2411-9636
 

Technical Note
Online Published: 30 Jun 2012
 


Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families

M. J. R. Abdunnabi.


Abstract
Thermosyphon solar water heaters are the best choice to be utilized in residential sector to provide the required hot water in Libya. These systems are autonomy in operation and as a result require less maintenance and hence low operation and initial costs than active system. ln this paper, GenOpt optimization technique provided in TRNSYS simulation program is used for sizing Thermosyphon systems to obtain the optimum size (namely V/A ratio) of Thermosyphon system that suits Libyan families according to the weather and operating conditions of Tripoli. The typical hot water load pattern and quantity of the Libyan families are taken from a field study conducted on a number of the solar systems for a whole year. Whereas, the typical weather data are taken from five-year measurements recorded at CSERS weather station. The results showed that the optimum storage tank volume to collector area ratio of Thermosyphon systems is between 49-60 Lit/m2 for the most common collector characteristics ratio (equation!!) and the auxiliary heater set point temperature ranges from (45-60C). 

Key words: Thermosyphon solar water heater, TRNSYS, optimization


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by M. J. R. Abdunnabi
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

M. J. R. Abdunnabi. Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. Sol. Energy Sustain. Dev.. 2012; 1(1): 25-31.

doi:10.51646/jsesd.v1i1.104



Web Style

M. J. R. Abdunnabi. Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. https://www.jsesd.org/?mno=302658185 [Access: November 12, 2026].

doi:10.51646/jsesd.v1i1.104



AMA (American Medical Association) Style

M. J. R. Abdunnabi. Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. Sol. Energy Sustain. Dev.. 2012; 1(1): 25-31.


doi:10.51646/jsesd.v1i1.104



Vancouver/ICMJE Style

M. J. R. Abdunnabi. Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. Sol. Energy Sustain. Dev.. (2012), [cited November 12, 2026]; 1(1): 25-31.


doi:10.51646/jsesd.v1i1.104



Harvard Style

M. J. R. Abdunnabi (2012) Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. Sol. Energy Sustain. Dev., 1 (1), 25-31.


doi:10.51646/jsesd.v1i1.104



Turabian Style

M. J. R. Abdunnabi. 2012. Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. Solar Energy and Sustainable Development, 1 (1), 25-31.


doi:10.51646/jsesd.v1i1.104



Chicago Style

M. J. R. Abdunnabi. "Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families." Solar Energy and Sustainable Development 1 (2012), 25-31.


doi:10.51646/jsesd.v1i1.104



MLA (The Modern Language Association) Style

M. J. R. Abdunnabi. "Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families." Solar Energy and Sustainable Development 1.1 (2012), 25-31. Print.


doi:10.51646/jsesd.v1i1.104



APA (American Psychological Association) Style

M. J. R. Abdunnabi (2012) Optimum Values of Tank Volume to Collector Area Ratios of Thermosyphon Solar Water Heaters for Libyan Families. Solar Energy and Sustainable Development, 1 (1), 25-31.


doi:10.51646/jsesd.v1i1.104